Request a Quote
Finished fittings on pallets in the Minwen warehouse in Nan'an

Gate, Ball, Globe & Check Valves

Threaded and flanged gate, ball, globe, check and pressure reducing valves for fire water and sprinkler lines, supplied in bulk to distributors, importers and OEM brands.

On this page
12 valve ranges: gate, ball, globe, check and pressure reducing
Order
200 pcs per model, mixed models in one container
Lead time
Samples 15–20 days, bulk 35–60 days from order confirmation

Which valve does which job

Each valve type does one job on a fire water line. A gate valve isolates a section. A ball valve shuts off with a quarter turn. A globe valve regulates flow. A check valve stops back-flow. A pressure reducing valve holds downstream pressure steady.

Pick a type to jump to its cards.

  1. Which valve type?

Valve ranges

Each card is one product or catalogue range. The store product comes first, then catalogue ranges. Tap a card or Get a quote and the quote form opens with that valve filled in. MOQ is 200 pcs per model, and models can be mixed in one container.

Gate valves

Full-bore isolation valves. Threaded DN15 to DN100; flanged up to DN300.

Threaded Ductile Iron Gate Valve DN15–DN50, PN16

Threaded Ductile Iron Gate Valve DN15–DN50, PN16

Size
DN15 / DN25 / DN50
Pressure rating
PN16
Body
Ductile iron
Appearance
Blue or red
Ends
BSP or NPT female thread
Model
Z15W-16Q

Isolation valve for small-bore fire water and sprinkler branch lines.

Gate Valve, Female Thread, DN15 to DN100

Gate Valve, Female Thread, DN15 to DN100

Size
DN15 to DN100 (1/2" to 4")
Ends
Female thread
Operation
Red handwheel

Isolation valve for fire water lines, hose reel feeds and pump rooms.

Models: 01-001A-00 to 01-001J-00, 01-004A-00 to 01-004J-00

Gate Valve, Fixed or Rising Stem, DN15 to DN100

Gate Valve, Fixed or Rising Stem, DN15 to DN100

Size
DN15 to DN100 (1/2" to 4")
Stem
Fixed (01-002) or rising (01-003)
Ends
Female thread

Isolation valve where a rising stem shows the open or closed position.

Models: 01-002A-00 to 01-002J-00, 01-003A-00 to 01-003J-00

Key-Operated (Lockable) Gate Valve, DN15 to DN100

Key-Operated (Lockable) Gate Valve, DN15 to DN100

Size
DN15 to DN100; 01-001C2-00 DN25
Operation
Square cap for loose key, no handwheel
Ends
Female thread

Gate valve that cannot be turned without the key, for tamper-prone locations.

Models: 01-010A-00 to 01-010J-00, 01-001C2-00

Flanged Gate Valve, DN15 to DN300

Flanged Gate Valve, DN15 to DN300

Size
DN15 to DN300 (1/2" to 12")
Ends
Flanged
Operation
Red handwheel

Flanged isolation valve for pump rooms and larger fire mains.

Models: 01-050A-00 to 01-050O-00

Flanged Gate Valve, Rising Stem, 100 mm

Flanged Gate Valve, Rising Stem, 100 mm

Inlet / outlet
100 mm / 100 mm
Ends
Flanged
Stem
Rising stem, blue handwheel

Flanged isolation valve for hydrant mains and pump rooms.

Models: 01-020-00

Ball valves

Quarter-turn shut-off for drains, test lines and small branches. Threaded or flanged, one with a built-in strainer.

Ball Valve with Lever Handle, DN15 to DN100

Ball Valve with Lever Handle, DN15 to DN100

Size
DN15 to DN100 (1/2" to 4")
Ends
Female thread
Appearance
Gold/bronze colour or silver colour

Quarter-turn shut-off for drains, test lines and small fire water branches.

Models: 02-001A-00 to J, 02-004A-00 to J, 02-005A-00 to J, 02-007A-00 to J, 02-016A-00 to J

Flanged Ball Valve, DN15 to DN200

Flanged Ball Valve, DN15 to DN200

Size
DN15 to DN200 (1/2" to 8")
Ends
Flanged
Operation
Lever handle

Flanged quarter-turn shut-off for pump and tank connections.

Models: 02-014A-00 to 02-014M-00

Ball Valve with Built-In Y-Strainer, DN15 to DN100

Ball Valve with Built-In Y-Strainer, DN15 to DN100

Size
DN15 to DN100 (1/2" to 4")
Ends
Female thread
Design
Ball valve and Y-strainer in one body

Shut-off and strainer in one fitting ahead of pumps, meters and pressure valves.

Models: 02-030A-00 to 02-030J-00

Globe valves

Regulating valves with a handwheel, threaded DN15 to DN100.

Threaded Globe Valve, DN15 to DN100

Threaded Globe Valve, DN15 to DN100

Size
DN15 to DN100 (1/2" to 4")
Ends
Female thread
Operation
Red handwheel; rising stem on 03-003

Regulating valve for test, drain and bypass lines.

Models: 03-001A-00 to J, 03-002A-00 to J, 03-003A-00 to J, 03-014A-00 to J

Check valves

Swing-disc check valves that let water flow one way only.

Threaded Swing Check Valve, DN15 to DN100

Threaded Swing Check Valve, DN15 to DN100

Size
DN15 to DN100 (1/2" to 4")
Ends
Female thread
Design
Swing disc, hex cap

Stops back-flow in pump discharge and fire water supply lines.

Models: 04-001A-00 to J, 04-002A-00 to J, 04-003A-00 to J

Pressure reducing valves

Valves that hold the pressure on a branch below the pressure of the main.

Pressure Reducing Valve, DN15 to DN50

Pressure Reducing Valve, DN15 to DN50

Size
DN15 to DN50 (1/2" to 2")
Ends
Female thread
Appearance
Gold colour; 06-017 silver colour

Holds downstream pressure steady on water branches fed from a high-pressure main.

Models: 06-001-00, 06-002-00, 06-005-00, 06-006-00, 06-007-00, 06-017-00 (A to F sizes)

Where each model is used

Valves are stocked by the part of the fire water system they go into.

  • Sprinkler and small fire water branch lines

    On small-bore sprinkler and fire water branches, the Threaded Ductile Iron Gate Valve DN15–DN50, PN16 isolates a section, with BSP or NPT female thread. The Ball Valve with Lever Handle, DN15 to DN100 gives quarter-turn shut-off on small branches. Where a branch is fed from a high-pressure main, the Pressure Reducing Valve, DN15 to DN50 holds the downstream pressure steady.

  • Pump rooms, tank connections and larger mains

    The Flanged Gate Valve, DN15 to DN300 and the Flanged Gate Valve, Rising Stem, 100 mm isolate pump rooms and hydrant mains. The Flanged Ball Valve, DN15 to DN200 shuts off pump and tank connections. The Threaded Swing Check Valve, DN15 to DN100 stops back-flow on pump discharge lines, and the Ball Valve with Built-In Y-Strainer, DN15 to DN100 goes ahead of pumps, meters and pressure valves.

  • Test, drain and bypass lines

    For lines that are opened to test or drain the system, stock the Threaded Globe Valve, DN15 to DN100, which regulates flow on test, drain and bypass lines with a red handwheel, rising stem on 03-003. For plain shut-off on drains and test lines, the Ball Valve with Lever Handle, DN15 to DN100 does it with a quarter turn. The catalogue photos show gold/bronze-coloured or silver-coloured versions.

  • Hose reel feeds and public locations

    On the line feeding a hose reel, the Gate Valve, Female Thread, DN15 to DN100 isolates the feed with a red handwheel. Where people could close a valve that must stay open, the Key-Operated (Lockable) Gate Valve, DN15 to DN100 has a square cap and turns only with the loose key. Where the valve position must be visible, the Gate Valve, Fixed or Rising Stem, DN15 to DN100 has a rising-stem version that shows open or closed.

How to choose a valve

After the valve type, use the details below to specify the model in your quote request.

End connection and size
Threaded valves have female threads from DN15 to DN100 (1/2 in to 4 in). Flanged gate valves go up to DN300 and flanged ball valves up to DN200.
Body material
Ductile iron is listed for the Z15W-16Q threaded gate valve, shown in blue or red.
Operation
Red handwheel on gate and globe valves, lever handle on ball valves, or a square cap for a loose key where the valve must not be turned by passers-by.
Working pressure and setting
Include the required working pressure. For a pressure reducing valve, include the inlet pressure and required outlet setting.

What to put on your inquiry

  1. Valve type and modelThe card name or catalogue code. Several models in one request is fine.
  2. Quantity per model200 pcs minimum; models can share a container.
  3. SizeDN or inch, per model.
  4. EndsFemale thread (name the standard) or flanged (name the flange standard).
  5. Body and operationYour specified material; handwheel, lever or key.
  6. Working pressure and settingRequired working pressure; inlet pressure and outlet setting for pressure reducing valves.
  7. Private labelLogo, handwheel colour, carton marking.

Your brand on the valve

Add these to your quote request and we answer for each model. More on the OEM and private label page.

  • LogoSend your logo file and say where it goes: handwheel, body or tag.
  • ColourName the body or handwheel colour your market expects.
  • Packaging markingSend your carton marking and label artwork.

The plant behind the valves

Minwen has made fire protection equipment in Nan’an, Quanzhou since 2001, and ships in bulk to distributors, importers and OEM brands. The figures cover the whole plant.

15,000 m²Plant area
20Production lines
193Staff
~45HQ containers a month
CE and CCC
Cover all current product lines.
ISO 9001
Quality management system certified to ISO 9001:2015 for fire equipment production.
UL
UL test reports available on request.
Worker grinding flanged valve bodies on the shop floor
Grinding flanged valve bodies before painting, Nan’an plant.
Rows of red-painted valve bodies on work tables
Painted valve bodies before assembly, Nan’an plant.

Questions buyers ask about our valves

Send the valve model, DN or size, connection requirements and quantity through the quote form. Request a quote for those models, with any outstanding connection or document requirements stated.

Which threads do the threaded valves have?

They have female threads. The ductile iron gate valve from our export store comes with BSP or NPT threads. For the other ranges, name the thread your market uses in the quote request.

How large do the flanged valves go?

Flanged gate valves go from DN15 to DN300, and flanged ball valves from DN15 to DN200. The flanged rising-stem gate valve is 100 mm.

What is a key-operated gate valve for?

It has a square cap instead of a handwheel, so it can only be turned with the loose key. Use it where people should not close the valve.

What does a gate valve do on a fire water line?

It isolates a section of the line: it is a full-bore shut-off valve. Ours go in fire water and sprinkler branch lines, hose reel feeds, pump rooms and hydrant mains.

Which gate valve types do you supply?

Threaded ductile iron (Z15W-16Q, PN16), female-thread gate valves, fixed- or rising-stem gate valves, and key-operated gate valves from DN15 to DN100. Flanged gate valves go up to DN300, plus a 100 mm flanged rising-stem valve.

What handles do the gate valves have?

A red handwheel on most gate valves, a blue handwheel on the 100 mm flanged rising-stem valve, and a square cap for a loose key on the key-operated valve.

MOQ, samples and lead times, certificates, private label and payment are answered once for every range in the ordering questions.

Request a valve quote

Tell us the valve type, size, end connection, thread, required working pressure and quantity per model. For pressure reducing valves, include the inlet pressure and required outlet setting.

  • MOQ 200 pcs per model, mixed models per container
  • Samples 15–20 days, bulk 35–60 days from order confirmation
  • Payment by T/T

Only your email is required. We reply from info@minwenfire.com.

Request received. We reply from info@minwenfire.com, so please check that this address is not filtered as spam.

While you wait, download the full catalogue (PDF) or send photos and drawings on WhatsApp +86 159 5986 7773.