Request a Quote
Finished fittings on pallets in the Minwen warehouse in Nan'an

Fire Sprinklers

DN15 glass bulb and fusible link sprinkler heads, upright or pendent, plus spare head cabinets, supplied in bulk to distributors, importers and OEM brands.

On this page
2 sprinkler heads and 1 spare head cabinet
Order
Sprinkler heads: 2,000 pcs per model; spare cabinets: baseline 200 pcs per model under per-model order terms
Lead time
Sample and bulk schedules follow confirmed order requirements (see timing terms)

Sprinkler selection and specification matrix

Compare our DN15 (1/2 in) glass bulb and fusible link sprinkler heads and spare head wall cabinets by thermal element, activation temperature, thread, body finish and per-model MOQ.

Both sprinkler head models come in upright or pendent orientation with standard response and chrome-plated brass bodies.

  1. What are you stocking?

Swipe sideways to read the full specification table →

Product / model Catalogue codes Size & thread / capacity Rating / dimensions Body & configuration Per-model MOQ
Glass Bulb Fire Sprinkler 68°C Store model DN15 / 1/2" (1/2 NPT); K80 68°C red glass bulb; standard response Chrome-plated brass; upright or pendent 2,000 pcs per model
Fusible Link Fire Sprinkler 74°C Store model DN15 / 1/2" 74°C / 165°F fusible link; standard response Chrome-plated brass; upright or pendent 2,000 pcs per model
Spare Sprinkler Cabinet 12-079, 12-080A, 12-080 12, 24 or 36 sprinkler heads 260 × 180 × 80, 350 × 180 × 80, 460 × 265 × 80 mm Red wall box marked 'Sprinkler Spares' Baseline 200 pcs per model

How to choose a sprinkler head

Compare the head type, orientation and thread before sending your quote request. Include the required temperature rating and quantity for each model.

Glass bulb or fusible link
The glass bulb model is rated at 68°C; the fusible link model at 74°C (165°F). State the head type and temperature required for your stock order.
Upright or pendent
Both heads come as upright or pendent. Specify the required orientation for each model on your inquiry.
Size and thread
Both heads are DN15 (1/2 in). The glass bulb head is K80 with a 1/2 NPT thread. Specify the required thread for each model.

What to put on your inquiry

  1. Head typeGlass bulb or fusible link.
  2. Quantity per model2,000 pcs per sprinkler model; models can share a container under the per-model order terms.
  3. OrientationUpright or pendent.
  4. ThreadThe thread your market uses, for example 1/2 NPT.
  5. Spare cabinets12, 24 or 36 heads, if you need them.
Fire sprinkler sample approval checklist

Your brand on the order

Add these to your quote request and we answer for each model. More on the OEM and private label page.

  • LogoSend your logo file and say where it goes: head boxes, cabinet door or cartons.
  • ColourName the cabinet colour your market expects.
  • Packaging markingSend your carton marking and label artwork.

Fire sprinkler products

Two sprinkler head types and one spare cabinet are shown below. Tap a card or Get a quote and the quote form opens with that product filled in.

Glass bulb sprinkler heads

The bulb breaks at its rated temperature and the head opens.

Glass Bulb Fire Sprinkler 68°C, DN15, Upright / Pendent

Glass Bulb Fire Sprinkler 68°C, DN15, Upright / Pendent

Size
DN15 / 1/2" (1/2 NPT)
Temperature
68°C red glass bulb
K-factor
K80
Response
Standard response
Body
Brass, chrome plated; upright or pendent

DN15 sprinkler head with a 68°C glass bulb, in upright or pendent orientation.

Spare sprinkler cabinets

A red wall box that keeps spare heads and a wrench on site.

Spare Sprinkler Cabinet for 12, 24 or 36 Heads

Spare Sprinkler Cabinet for 12, 24 or 36 Heads

Capacity
12, 24 or 36 sprinkler heads
Size (W x H x D)
260 x 180 x 80, 350 x 180 x 80, 460 x 265 x 80 mm
Finish
Red, 'Sprinkler Spares' on door

Wall box that keeps spare heads and a wrench next to the sprinkler valve set.

Models: 12-079, 12-080A, 12-080

Match the product to your stock order

Two heads and one cabinet cover three stocking needs.

  • Glass bulb heads for stock orders

    The Glass Bulb Fire Sprinkler 68°C, DN15, Upright / Pendent has a red 68°C glass bulb, K80, standard response and a chrome-plated brass body, with a 1/2 NPT thread. Specify upright or pendent for each model in your stock order. The sprinkler MOQ is 2,000 pcs per model; both orientations can share a container, subject to the per-model order conditions.

  • 74°C fusible link heads

    The Fusible Link Fire Sprinkler 74°C, DN15, Upright / Pendent uses a solder link rated at 74°C (165°F). It is DN15, standard response, in chrome-plated brass, upright or pendent. Specify the required thread and orientation for each model on your inquiry.

  • Spare heads kept at the valve set

    Every sprinkler order can carry the box that keeps spares on site. The Spare Sprinkler Cabinet for 12, 24 or 36 Heads is a red wall box marked ‘Sprinkler Spares’ that holds spare heads and a wrench next to the sprinkler valve set. Sizes run 260 x 180 x 80 to 460 x 265 x 80 mm. Spare cabinets have a baseline MOQ of 200 pcs per model, subject to the order conditions; the 2,000 pcs sprinkler MOQ applies to sprinkler heads.

Minwen Fire in Nan’an

Minwen has made fire protection equipment in Nan’an, Quanzhou since 2001, and ships in bulk to distributors, importers and OEM brands. The figures cover the whole plant.

15,000 m²Plant area
20Production lines
193Staff
~45HQ containers a month
CE and CCC
CE and CCC applicability depends on the product and model.
ISO 9001
ISO 9001 certified quality management system.
MOQ
2,000 pcs per sprinkler model; spare cabinets have a baseline of 200 pcs per model. Per-model order conditions apply.
Hands assembling sprinkler heads at a bench
Assembling sprinkler heads by hand, Nan’an plant.
Sprinkler heads moving along an assembly track
Sprinkler heads on the assembly line, Nan’an plant.

Sprinkler range and ordering questions

Answers about this range. For anything else, write on WhatsApp or by email.

Glass bulb or fusible link: what is the difference?

Both keep the head closed until a fire heats it. A glass bulb breaks at 68°C; a fusible link is a solder joint that melts at 74°C (165°F).

What is the MOQ for sprinkler heads?

2,000 pcs per sprinkler model. Spare sprinkler cabinets have a baseline of 200 pcs per model. Models can share one container with products from our other ranges, subject to the per-model order conditions.

What size and thread are the sprinkler heads?

Both heads are DN15 (1/2 in). The glass bulb head is K80 with a 1/2 NPT thread; specify the required thread for each model.

What are the sprinkler heads made of?

Brass, chrome plated, on both the glass bulb and the fusible link heads.

Which sprinkler head types are available?

Glass bulb heads (68°C) and fusible link heads (74°C), each upright or pendent, both standard response.

For this range, see the order and timing conditions below. More on certificates, private label and payment is in the ordering questions.

Request a sprinkler quote

Tell us the head type, temperature, orientation, thread and quantity per model.

  • Sprinkler heads: 2,000 pcs per model, with the model, specification, certification, packaging and delivery requirements confirmed. Spare sprinkler cabinets: baseline 200 pcs per model, subject to product, configuration, certification, mixed-order structure, packaging and schedule. Mixed orders are accepted; each model must still meet its applicable minimum.
  • Samples: 15–20 days after the product, specification, certification, branding and sample requirements are confirmed. Bulk production: 35–60 days from order confirmation, after specifications, certification requirements, packaging, quantity and the production schedule are confirmed.
  • Payment by T/T

Only your email is required. We reply from info@minwenfire.com.

Request received. We reply from info@minwenfire.com, so please check that this address is not filtered as spam.

While you wait, download the full catalogue (PDF) or send photos and drawings on WhatsApp +86 159 5986 7773.